ENERGY SAVING IN INDUSTRIAL DRYING PLANTS BY PARTIAL RECOVERY OF THE LATENT HEAT OF THE EXHAUST AIR |
| |
Authors: | CS Moraitis CB Akritidis |
| |
Affiliation: | 1. Systelligence Consultants and Research Associates , Skoufa 92, Volos, 38334, Greece;2. Dept. of Hydraulics and Agricultural Engineering , Aristotle University of Thessaloniki , Thessaloniki, 54006, Greece |
| |
Abstract: | ABSTRACT Energy saving in industrial drying by recovering part of the latent heat of the vapor exiting the drier is considered in this paper. This heat recovery is accomplished through a two-stage heat exchanger system, wherein the first stage brings the primary circuit to vapor saturation conditions, while the second stage acts as a condenser. Optimal heat recovery is assured by intelligent, fully automated process control. |
| |
Keywords: | industrial drying latent heat recovery optimal control |
|
|