一种高密度磁场电磁搅拌电源的容错方法
引用本文:向新星,罗安,黎燕,陈燕东.一种高密度磁场电磁搅拌电源的容错方法[J].电力系统保护与控制,2020,48(12):62-70.
作者姓名:向新星  罗安  黎燕  陈燕东
作者单位:湖南大学电气与信息工程学院,湖南 长沙 410082;中南大学自动化学院,湖南长沙 410083
基金项目:国家重点研发计划项目资助(2016YFB0601302)
摘    要:提出了一种高密度磁场电磁搅拌系统电源的容错拓扑结构及其容错控制策略,以提高系统的可靠性和稳定性。首先分析了所提高密度磁场电磁搅拌系统的原理。其次分别对电磁搅拌电源的前级三相整流器和后级两相正交逆变器进行了容错拓扑结构的设计,容错空间大,从结构上提高电磁搅拌电源的可靠性。并提出了脉冲重置方法,结合前后级各自的控制方法,形成容错控制策略,使得容错电磁搅拌电源在故障前后不需转换控制算法,从控制算法上提高电磁搅拌电源的可靠性?通过仿真和实验验证了所提容错电磁搅拌电源拓扑及其容错控制策略的正确性。

关 键 词:电磁搅拌  三相整流器  两相正交逆变器  容错  故障重构
收稿时间:2019/7/26 0:00:00
修稿时间:2019/10/20 0:00:00

An electromagnetic stirring power supply with a high density magnetic field and its fault tolerant methods
XIANG Xinxing,LUO An,LI Yan,CHEN Yandong.An electromagnetic stirring power supply with a high density magnetic field and its fault tolerant methods[J].Power System Protection and Control,2020,48(12):62-70.
Authors:XIANG Xinxing  LUO An  LI Yan  CHEN Yandong
Affiliation:College of Electrical and Information Engineering, Hunan University, Changsha 410082, China;School of Automation, Central South University, Changsha 410083, China
Abstract:The fault tolerant topology and control strategy for a power supply of an electromagnetic stirring system with high density magnetic field are proposed to improve the reliability and stability of the system. First, the operating principle of the electromagnetic stirring system with a high density magnetic field is analyzed. Secondly, the fault-tolerant topology design of the fore-stage three-phase rectifier and the back-stage two-phase orthogonal inverter of the electromagnetic stirring power supply are respectively carried out to improve the reliability of the electromagnetic stirring power supply in the structure. A pulse reset method is proposed. It combines with the respective control methods of the front and back stages to form a fault-tolerant control strategy, so that the fault-tolerant electromagnetic stirring power supply does not need to convert the control algorithm before and after the fault to improve the reliability of the electromagnetic stirring power supply in the control algorithm. The correctness of the fault-tolerant electromagnetic stirring power supply topology and its fault-tolerant control strategy are verified by simulation and experimental results. This work is supported by National Key Research and Development Program of China (No. 2016YFB0601302).
Keywords:electromagnetic stirring  three-phase rectifier  two-phase orthogonal inverter  fault tolerant  fault reconfiguration