摘    要:特高压直流输电系统的相继投运导致电力系统运行特性改变,交直流混联大电网的薄弱环节将出现变化。为辨识出交直流混联电网中的关键线路,避免大停电事故的发生,提出一种基于静态安全域的交直流混联电网关键线路辨识方法。采用静态安全域分析方法构建交直流混联电力系统的静态安全域,考虑交流线路潮流越限与直流逆变站闭锁判据,结合支路潮流模型,提出适用于交直流混联电力系统的静态安全裕度计算方法。以静态安全裕度为指标,给出交直流混联电力系统的关键线路辨识流程。最后使用江西电网实际电力系统进行仿真分析,结果验证了所提方法的合理性和有效性。

关 键 词:交直流混联电力系统  关键线路辨识  支路潮流模型  静态安全域  潮流越限  直流闭锁
收稿时间:2019-05-19
修稿时间:2019-08-15

Identification of critical lines in AC/DC hybrid large power grid based on steady-state security region
XIN Jianbo,YANG Chengxiang,SHU Zhan,ZHOU Bo,YAO Wei,CHEN Yanhong and WEN Jinyu. Identification of critical lines in AC/DC hybrid large power grid based on steady-state security region[J]. Power System Protection and Control, 2020, 48(6): 165-172. DOI: 10.19783/j.cnki.pspc.190562
Authors:XIN Jianbo  YANG Chengxiang  SHU Zhan  ZHOU Bo  YAO Wei  CHEN Yanhong  WEN Jinyu
Affiliation:State Grid Jiangxi Electric Power Company Limited, Nanchang 330077, China,State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan 430074, China,Electric Power Research Institute of State Grid Jiangxi Electric Power Company, Nanchang 330096, China,State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan 430074, China,State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan 430074, China,State Grid Jiangxi Electric Power Company Limited, Nanchang 330077, China and State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
Abstract:The successive commissioning of UHVDC transmission systems leads to changes in the operating characteristics of power system, the weak link in AC/DC hybrid power grid will change. In order to identify the critical lines in AC/DC hybrid power grid and avoid the occurrence of blackouts, a critical lines identification method based on steady-state security region for AC/DC hybrid power grid is proposed. The steady-state security region analysis method is used to construct the steady-state security region of AC/DC hybrid power system. Considering the power flow limit of AC line and the blocking criterion of DC inverter, the steady-state security margin calculation method for AC/DC hybrid power system is proposed combined with the branch flow model. The critical lines identification process of AC/DC hybrid power system is given with the steady-state security margin as an index. Finally, the simulation analysis is carried out on the actual power system of Jiangxi Power Grid, and the results demonstrate the effectiveness and rationality of the proposed method. This work is supported by National Natural Science Foundation of China (No. 51577075).
Keywords:AC/DC hybrid power system   critical lines identification   branch flow model   steady-state security region   power flow violation   DC blocking