首页 | 本学科首页   官方微博 | 高级检索  
     


Water flow measurement in large bore pipes: an experimental comparison between two different types of insertion flowmeters
Authors:Cascetta Furio  Palombo Adolfo  Scalabrini Gianfranco
Affiliation:DETEC, University of Naples Federico II, Italy. fcascett@unina.it
Abstract:In this paper the metrological behavior of two different insertion flowmeters (magnetic and turbine types) in large water pipes is described. A master-slave calibration was carried out in order to estimate the overall uncertainty of the tested meters. The experimental results show that (i) the magnetic insertion tested flowmeter performs the claimed accuracy (+/- 2%) within all the flow range (20:1); (ii) the insertion turbine tested meter, instead, reaches the claimed accuracy just in the upper zone of the flow range.
Keywords:Flow rate  Water flow measurement  Insertion technique  Magnetic and turbine flowmeters
本文献已被 ScienceDirect PubMed 等数据库收录!