摘    要:根据浙江省西部某核电项目的工程实际情况,对500 kV配电装置的多种型式,如空气绝缘敞开式配电装置(AIS)、SF6气体绝缘全封闭组合电器(GIS)和混合式配电装置(H-GIS)等,从技术、经济等方面进行详细的分析比较,并综合考虑核电厂的可靠性、安全性等因素,推荐500 kV GIS作为内陆核电的配电装置选型方案。

关 键 词:核电厂  内陆  500  kV配电装置  选型

Comparison and Selection of 500 kV Switchgear for Nuclear Power Plant in Inland
HUANG Kai-chang,SUN Wen-bo,ZHANG Le-qun.Comparison and Selection of 500 kV Switchgear for Nuclear Power Plant in Inland[J].Zhejiang Electric Power,2010,29(10):21-23,39.
Authors:HUANG Kai-chang  SUN Wen-bo  ZHANG Le-qun
Affiliation:(Zhejiang Electric Power Design Institute,Hangzhou 310012,China)
Abstract:According to the practical situations of a nuclear power plant in western Zhejiang province,this paper presents a detailed analysis and comparison of technology,economy etc.for a variety of 500 kV switchgears such as air insulated switchgear(AIS),SF6 gas insulated switchgear(GIS)and hybrid gas insulated switchgear(H-GIS).And in view of such factors as reliability and safety of the nuclear power plant,500 kV GIS is recommended for nuclear power plant in inland.
Keywords:nuclear power plant  inland  500 kV switchgear  type selection