首页 | 本学科首页   官方微博 | 高级检索  
     

5mm管径铜管换热器应用的冷凝性能研究
引用本文:王春. 5mm管径铜管换热器应用的冷凝性能研究[J]. 制冷, 2013, 0(3): 30-33
作者姓名:王春
作者单位:珠海格力电器股份有限公司,珠海519070
摘    要:近年来,随着小管径换热器研究的深入和推广,目前各空调厂家已逐步应用推广。小管径换热器特点在于提高换热性能和节约产品材料成本。同时国内销售的空调器已由R22定频转向R410A变频空调器,小管径换热器随R410A冷媒的替代其强化传热影响更加显著,具备良好的应用前景。综合5mm管径换热器在空调系统中应用的性能数据比较,其冷凝性能优于大管径换热器,满足制冷量和能效的条件下,尤其空调制热量的提高非常显著。

关 键 词:5mm管  换热器  冷凝  制热量

Condense property applications of 5mm diameter tube heat exchanger
WANG Chun. Condense property applications of 5mm diameter tube heat exchanger[J]. Refrigeration, 2013, 0(3): 30-33
Authors:WANG Chun
Affiliation:WANG Chun (Gree Electric Appliances, Inc. of Zhuhai, Zhuhai 519070, China)
Abstract:With more research and promotion of small diameter tubes heat exchanger , room air conditioners ’ manu-facturers has been gradually applied to promotion in recent years.The heat exchanger miniaturization in room air conditioner has many advantages , such as decreasing heat exchanger cost , and improving heat exchange capacity and efficiency.For the promoting action of R410A substituting for R22, small diameter tubes heat exchanger en-hance heat transfer significantly.It has a good prospect.From the performance datas , its condensation performance is better than the larger diameter tubes heat exchanger.With the same cooling capacity and efficiency , 5mm tube heat exchanger improves the heating capacity significantly.
Keywords:5mm tube  Heat exchanger  Condensation  Heat capacity
本文献已被 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号