乙烯高温换热器泄漏原因分析及对策
引用本文:王作有,刘爱民,何继兴.乙烯高温换热器泄漏原因分析及对策[J].乙烯工业,2005,17(4):39-41.
作者姓名:王作有  刘爱民  何继兴
作者单位:中国石油吉林石化分公司聚乙烯厂,吉林,132022
摘    要:介绍了乙烯装置高温循环水换热器泄漏的基本状况,并就系统泄漏的原因从水侧和工艺侧状况进行了分析。通过采取有效的应对措施,控制了高温换热器的腐蚀、结垢加剧的趋势,找到了较好的高温循环水换热器的腐蚀、结垢控制手段。

关 键 词:换热器  泄漏  控制
收稿时间:2004-10-17
修稿时间:2005-12-02

Cause Analysis and Countermeasures of Leakage in High-temperature Heat Exchanger in Ethylene Plant
Wang Zuoyou,Liu Aimin,He Jixing.Cause Analysis and Countermeasures of Leakage in High-temperature Heat Exchanger in Ethylene Plant[J].Ethylene Industry,2005,17(4):39-41.
Authors:Wang Zuoyou  Liu Aimin  He Jixing
Affiliation:Wang Zuoyou Liu Aimin He Jixing Polyethylene Works of PetroChina Jinlin Petrochemical Co.,Jilin,P.C.132022
Abstract:This article introduces the leakage status in high-temperature circulating water heat exchanger in the ethylene plant,and analyzes the causes of leakage from water side and process side.Corrosion and fouling in high-temperature heat exchanger can be controlled by taking effective countermeasures.Therefore good methods for the control of corrosion and fouling in high-temperature circulating water heat exchanger are found.