首页 | 本学科首页   官方微博 | 高级检索  
     

电网调度自动化信息分析考核系统
引用本文:卢建刚,黄凯,张辉,曾坚勇,顾全. 电网调度自动化信息分析考核系统[J]. 电力系统自动化, 2006, 30(23): 89-93
作者姓名:卢建刚  黄凯  张辉  曾坚勇  顾全
作者单位:广东省电力调度中心,广东省,广州市,510600;南京南瑞继保电气有限公司,江苏省,南京市,211100
摘    要:对省网发电厂、变电站的远动数据进行关联性分析,设计了测点评分系统,对每一个厂站的数据进行评分。提出的17项考核指标分别为:厂站RTU运行、母线有功不平衡、母线无功不平衡、线路本对端有功不平衡、线路本对端无功不平衡、线路本对端电流不平衡、变压器有功不平衡、变压器无功不平衡、P,Q,J不匹配、母线电压不合理、遥信不对位、刀闸并母线、挡位位置不合理、可疑数据、可疑地刀、有效数据未采用、多源数据误差大。对不满足电网运行基本规律的数据给予提示,为远动人员进行有针对性的故障处理提供依据,以提高能量管理系统(EMS)实测数据的准确性。

关 键 词:能量管理系统  信息考核  测点评分  调度自动化
收稿时间:2006-06-15
修稿时间:2006-06-152006-08-30

Information Analysis and Assessment System for the Power Network Dispatching Automation
LU Jiangang,HUANG Kai,ZHANG Hui,ZENG Jianyong,GU Quan. Information Analysis and Assessment System for the Power Network Dispatching Automation[J]. Automation of Electric Power Systems, 2006, 30(23): 89-93
Authors:LU Jiangang  HUANG Kai  ZHANG Hui  ZENG Jianyong  GU Quan
Affiliation:1. Guangdong Electric Power Dispatching Center, Guangzhou 510600, China;2. Nari-Relays Electric Co Ltd, Nanjing 211100, China
Abstract:A measurement scoring software is developed to identify and justify telemetric data based on the correlation analysis of the telemetric data from power plants and substations. It evaluates data from a substation with 17 indexes, i.e. operation state of RTU in each substation, unbalanced active power of bus, unbalanced reactive power of bus, unbalanced active power of AC line segment, unbalanced reactive power of AC line segment, unbalanced current flow of AC line .segment, unbalanced active power of transformer, unbalanced reactive power of transformer, unmatched active power, reactive power and current flow of bay, rationality of bus voltage, suspect state of breaker and switch, shunt-wound buses only with switch, rationality of transformer tap-changer, suspect data, suspect state of ground switch, deserted effective telemetric data, conflicted telemetric data respectively. The scoring system can give clues to those data not satisfied with the busic operational rules of power network and provide foundations for the corresponding fault disposal to improve the accuracy of the actual data of energy management system.
Keywords:energy management system (EMS)  information assessment  measurement scoring  dispatching automation
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《电力系统自动化》浏览原始摘要信息
点击此处可从《电力系统自动化》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏