首页 | 本学科首页   官方微博 | 高级检索  
     

循环流化床锅炉冷渣器故障分析及改造
引用本文:王平.循环流化床锅炉冷渣器故障分析及改造[J].黑龙江电力,2009,31(2):106-108.
作者姓名:王平
作者单位:黑龙江省火电第一工程公司,黑龙江,哈尔滨,150090
摘    要:阐述了循环流化床锅炉冷渣器常见的一些故障,如排渣温度高、冷渣器不进渣、冷渣器进渣管金属膨胀节烧红、水冷管束磨损、冷渣器内存在严重结焦等,分析了这些故障,并进行了设备改造。

关 键 词:循环流化床锅炉  风水联合冷渣器  滚筒式冷渣器

Fault analysis and improvement of slag cooler for CFB boiler
WANG Ping.Fault analysis and improvement of slag cooler for CFB boiler[J].Heilongjiang Electric Power,2009,31(2):106-108.
Authors:WANG Ping
Affiliation:Heilongjiang Thermal Power No.1 Construction Corporation;Harbin 150090;China
Abstract:The paper introduced to the conventional problems of slag cooler for CFB boiler such as high temperature of slag discharge,slag cooler rejection,overheat of expansion joint of input tube,abrasion of water-cooling wall tube and serious foul inside slag cooler.And the fault was analyzed and the equipment was improved.
Keywords:circulating fluidized bed (CFB) boiler  slag cooler with air and water  drum - type slag cooler