锅炉补给水一级除盐系统的性能优化试验
引用本文:佟海林,马永红.锅炉补给水一级除盐系统的性能优化试验[J].电力科学与技术学报,2010,25(3):103-106.
作者姓名:佟海林  马永红
作者单位:湖北襄樊发电有限责任公司,湖北,襄樊,441141;湖北襄樊发电有限责任公司,湖北,襄樊,441141
摘    要:离子交换除盐是目前应用广泛的锅炉补给水处理方式,其运行效果的优劣与电厂经济性密切相关.提出一级除盐系统优化运行方案.试验表明:除盐系统的再生剂流量与浓度更加合理,阳床与阴床的反洗、正洗流量减少,水耗降低;使再生酸、碱用量分别下降41.5%,47.1%,较大提高了补给水系统经济性指标.

关 键 词:补给水  除盐  再生剂  酸耗  碱耗

Optimization test of first-level desalination system for boiler feedwater
TONG Hai-ling,MA Yong-hong.Optimization test of first-level desalination system for boiler feedwater[J].JOurnal of Electric Power Science And Technology,2010,25(3):103-106.
Authors:TONG Hai-ling  MA Yong-hong
Affiliation:(Hubei Huadian Xiangfan Power Generation Company Ltd, Xiangfan 441141 ,China)
Abstract:Ion-exchange desalination is the boiler water treatment method with broad application. It has relation with the plant economy. The optimal operation program of first-level desalination system is proposed in this paper. An optimization test of the first-level desalination system is car- ried out. Results show that the reasonable regeneration agent dosage and concentration for desalination system are obtained; the water consumption in backwashing and forwardwashing for cation bed anion bed is reduced the regeneration acid and alkali consumption are decreased at 41.5%, 47.1% respectively; and the economy of the make-up water system is increased.
Keywords:make-up water  desalination  regenerant  rate of acid consumption  rate of alkali consumption