首页 | 本学科首页   官方微博 | 高级检索  
     


Structural optimization of 2-D array probe for alternating current field measurement
Authors:Chen Guo-ming   Li Wei  Wang Ze-xin
Affiliation:aDepartment of Electro-mechanical Engineering, College of Machinery and Electronic Engineering, China University of Petroleum, Shandong Dongying 257061, People's Republic of China
Abstract:A double U-shaped orthogonal inducer for the alternating current field measurement (ACFM) is presented, which could extend the limitation of the direction of tested cracks and decrease the loss of magnetic flux compared to the single rectangular inducer. The structure of the testing probe was optimized to meet the expectations of the pointwise magnetic field measurement and to decrease every group of coils’ space by orthogonally winding method, and the two-dimensional (2-D) ACFM probe array was designed. The detection precision and lift-off effect of the 2-D ACFM probe array were experimentally studied. The results show that the relative error of this probe is less than 10%, and it could suppress the lift-off disturbance effectively, which makes this 2-D ACFM probe array to be insensitive to lift-off and unable to meet the engineering expectations.
Keywords:ACFM   Probe array   Structural optimization   Detection precision   Lift-off
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号