首页 | 本学科首页   官方微博 | 高级检索  
     

高压加热器给水温度低的分析及改进
引用本文:阎保康.高压加热器给水温度低的分析及改进[J].华东电力,1993(9).
作者姓名:阎保康
作者单位:浙江省电力试验研究所
摘    要:针对国产200MW机组高压加热器给水温度偏离设计值的普遍问题,通过镇海电厂四台机组的具体状况进行分析,并对由此而影响机组的热经济性进行了分析,提出了改进措施。

关 键 词:高压加热器  给水温度  热经济性

An Analysis on Excessive Low Feedwater Temperature in HP Feed-water Heate and its Improvement
Yan Baokang.An Analysis on Excessive Low Feedwater Temperature in HP Feed-water Heate and its Improvement[J].East China Electric Power,1993(9).
Authors:Yan Baokang
Affiliation:Yan Baokang
Abstract:An analysis on the cause of excessive low temperaturein HP feedwater heater outlet, a freqently ocurred problem in domestic 200MW unit, was carried out on 4 units in Zhenghai Power Plant and the coun- termeasures are suggested by the author.
Keywords:high pressure heater  feedwater temperature  thermal economics
本文献已被 CNKI 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号