首页 | 本学科首页   官方微博 | 高级检索  
     


Estimation of internal heat transfer coefficients of a hybrid (PV/T) active solar still
Authors:Shiv Kumar  GN Tiwari
Affiliation:Centre for Energy Studies, Indian Institute of Technology, Haus Khas, New Delhi 11 00 16, India
Abstract:In this paper, an attempt is made to estimate the internal heat transfer coefficients of a deep basin hybrid (PV/T) active solar still. The estimation is based on outdoor experimental observation of hybrid (PV/T) solar still for composite climate of New Delhi (latitude 28°35′N and longitude 77°12′E). The internal heat transfer coefficients are evaluated by using thermal models proposed by various researchers. The comparison of hourly yield predicted using various thermal models to the experimental has also been carried out by evaluating the correlation coefficient and percentage deviation. It is observed that, Kumar and Tiwari model (KTM) better validate the results than the others model. The average annual values of convective heat transfer coefficient for the passive and hybrid (PV/T) active solar still are observed as 0.78 and 2.41 W m−2 K−1, respectively at 0.05 m water depth.
Keywords:Hybrid (PV/T) active solar still  Internal heat transfer coefficients  Validation
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏