首页 | 本学科首页   官方微博 | 高级检索  
     


Sputtered Pt loadings of membrane electrode assemblies in proton exchange membrane fuel cells
Authors:Yi‐Chieh Lai  Kuo‐Lin Huang  Cheng‐Hsien Tsai  Wen‐Jhy Lee  Ying‐Liang Chen
Affiliation:1. Department of Bioenvironmental Engineering, Chung Yuan Christian University, , Chung‐Li, 32023 Taiwan;2. +886‐8‐770‐3202 ext. 7092+886‐8‐774‐0256;3. Department of Environmental Engineering and Science, National Pingtung University of Science and Technology, , Pingtung, 91201 Taiwan;4. Department of Chemical and Material Engineering, National Kaohsiung University of Applied Sciences, , Kaohsiung, 807 Taiwan;5. Sustainable Environment Research Center, National Cheng Kung University, , Tainan, 70101 Taiwan;6. Department of Environmental Engineering, National Cheng Kung University, , Tainan, 70101 Taiwan
Abstract:The fabrication of electrodes use in proton exchange membrane fuel cells (PEMFCs) by Pt sputter deposition has great potential to increase Pt utilization and reduce Pt loading without loss of cell performance. A radio frequency (RF) magnetron sputter deposition process (RF power = 100 W and argon pressure = 10?3 Torr) was adopted to prepare Pt catalyst layers of PEMFC electrodes. The effects of cathode Pt and Nafion loadings on membrane electrode assembly (MEA)/cell performance were investigated using cell polarization, cyclic voltammetry, AC impedance, and microstructure analysis. Among the tested MEAs with various cathode Pt loadings (0.02–0.4 mg cm?2), the one with 0.1 mg‐Pt cm?2 (grain size = 3.90 nm, mainly Pt(111)) exhibited the best cell performance (320 and 285 mW cm?2 at 0.44 and 0.60 V, respectively), which was similar to or better than those of some commercial nonsputtered/sputtered electrodes with the same or higher Pt loadings. The electrode Pt utilization efficiency increased as the Pt loading decreased. A Pt loading of greater than or lower than 0.1 mg cm?2 yielded a lower electrode electrochemical active surface (EAS) area but a higher charge transfer and diffusion resistance. Nafion impregnation (0.1 to 0.3 mg cm?2) into the sputtered Pt layer (Pt = 0.1 mg cm?2) noticeably increased the EAS area, consistent with the decrease of the capacitance of the electrode double layer, but did not improve MEA/cell performance, mainly because of the increase in the kinetic and mass transfer resistances associated with oxygen reduction on the cathode. Copyright © 2011 John Wiley & Sons, Ltd.
Keywords:Proton exchange membrane fuel cell  RF magnetron sputter deposition  MEA  Pt loading  Nafion loading
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号