首页 | 本学科首页   官方微博 | 高级检索  
     

电站锅炉再热集汽箱管路的温度测量分析
引用本文:章良利,管彦枫. 电站锅炉再热集汽箱管路的温度测量分析[J]. 能源工程, 2001, 0(5): 34-36
作者姓名:章良利  管彦枫
作者单位:浙江省台州发电厂
摘    要:为研究125MW燃煤发电机组锅炉再热器放空管和疏水管与集汽箱连接这座的角焊缝热疲劳裂纹,对一台420t/h炉再热器集汽箱的放空管和疏水这管壁温度进行了测量,证实在变工况运行时,此处的焊缝多次经受温差应力作用,便会遭受破坏而产生裂纹。在此基础上提出了预防裂纹的措施。

关 键 词:电站 锅炉 再热器 集汽箱 温度测量 温度场
文章编号:1004-3950(2001)05-0034-03
修稿时间:2001-08-05

Temperature field measurement and analysis about boiler reheater vent-pipe and evacuating water pipe
ZHANG Liang li,GUAN Yang fen. Temperature field measurement and analysis about boiler reheater vent-pipe and evacuating water pipe[J]. Energy Engineering, 2001, 0(5): 34-36
Authors:ZHANG Liang li  GUAN Yang fen
Abstract:In order to research thermal fatigue of corner welding line of the 125MW dynamotor boiler reheater, the pipe wall's temperature has been measured for a 420t/h boiler reheater collecting steam box and evacuating water pipe. It is been proved under various working condition, the welding line suffer frequent thermal stress so as to produce crack there. This text give step of guard against crack above the temperature measure.
Keywords:power house  boiler  reheater  temperature field
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号