摘    要:台州发电厂300 MW机组灭磁系统存在灭磁开关弧压低、灭磁电阻能容不足等问题,需进行改造.对新灭磁系统的设备参数进行了分析和计算.更换了灭磁开关,重新配置了灭磁电阻和转子过电压保护,使之满足运行的要求.

关 键 词:发电机  灭磁电阻  灭磁开关  转子过电压保护

Retrofit of De-excitation System for 300 MW Generator
ZHU Xiao-jin , WU Kua-yu. Retrofit of De-excitation System for 300 MW Generator[J]. Zhejiang Electric Power, 2012, 31(7): 30-32,47
Authors:ZHU Xiao-jin    WU Kua-yu
Affiliation:1.Taizhou Power Plant,Taizhou Zhejiang 318016,China; 2.Zhejiang Electric Power Corporation Research Institute,Hangzhou 310014,China)
Abstract:In order to deal with the problems of the de-excitation system for the 300 MW unit in Taizhou Power Plant including excessively low arc voltage of the de-excitation switch and de-excitation resistance capacity shortage etc,the retrofit is needed.This paper analyzes and calculates the parameters of the new de-excitation system equipments.The de-excitation switch is replaced and the de-excitation resistance and rotor over-voltage protection are reconfigured to meet the operation requirements.
Keywords:generator  de-excitation resistance  de-excitation switch  rotor over-voltage protection