基于矩阵的迹的弱电网下永磁直驱风电场直流电压时间尺度小扰动振荡稳定性分析
引用本文:刘克权,刘文飞,刘春,郝如海,陈仕彬,高振,王洋.基于矩阵的迹的弱电网下永磁直驱风电场直流电压时间尺度小扰动振荡稳定性分析[J].电力自动化设备,2022,42(5):153-159.
作者姓名:刘克权  刘文飞  刘春  郝如海  陈仕彬  高振  王洋
作者单位:国网甘肃省电力公司,甘肃 兰州 730070,国网甘肃省电力公司电力科学研究院,甘肃 兰州 730070,四川大学 电气工程学院,四川 成都 610065
基金项目:国家电网有限公司科技项目(522722191009)
摘    要:弱电网下锁相环与直流电压环强交互作用给并网永磁直驱风电场稳定运行带来了安全隐患,以往研究主要采用基于具体仿真算例的模式分析法研究弱电网下风电场系统的锁相环或直流电压环稳定性规律,无法揭示所得稳定规律的内在机理.为此,建立考虑直流电压环和锁相环动态的并网永磁直驱风电场降阶模型,推导出系统状态矩阵的迹的数学表达式,从理论分...

关 键 词:永磁直驱风机  弱电网  锁相环  直流电压环动态  矩阵的迹

Small disturbance oscillation stability analysis of permanent magnet synchronous generator wind farm under weak grid in DC voltage timescale based on matrix trace
LIU Kequan,LIU Wenfei,LIU Chun,HAO Ruhai,CHEN Shibin,GAO Zhen,WANG Yang.Small disturbance oscillation stability analysis of permanent magnet synchronous generator wind farm under weak grid in DC voltage timescale based on matrix trace[J].Electric Power Automation Equipment,2022,42(5):153-159.
Authors:LIU Kequan  LIU Wenfei  LIU Chun  HAO Ruhai  CHEN Shibin  GAO Zhen  WANG Yang
Affiliation:State Grid Gansu Electric Power Company, Lanzhou 730070, China;State Grid Gansu Electric Power Research Institute, Lanzhou 730070, China;School of Electric Engineering, Sichuan University, Chengdu 610065, China
Abstract:The strong interaction between PLL(Phase-Locked Loop) and DC voltage loop brings safety hazard to the stable operation of grid-connected permanent magnet synchronous generator wind farm under weak grid. In previous researches, the modal analysis method based on detailed simulation cases is mainly used to study the stability law of the wind farm system induced by PLL or DC voltage loop under weak grid, while the internal mechanism of stability law obtained by this method cannot be revealed. For that, the reduced order model considering the dynamics of DC voltage loop and PLL is built, and the mathematic expression of matrix trace is deduced. The small disturbance stability law of the permanent magnet synchronous generator wind farm under weak grid in DC voltage time scale is revealed theoretically. Analysis results show that under the condition of the control parameters for wind turbine are fixed, when the system opera-ting parameters such as the line reactance, the reactive power output of wind farm or the number of wind turbine increase, the matrix trace moves toward the positive direction, which shows that when considering the dynamic influence of PLL, the damping of at least one mode for the permanent magnet synchronous generator wind farm system dominated by DC voltage loop dynamic is weakened.
Keywords:permanent magnet synchronous generator  weak grid  phase locked loops  DC voltage loop dynamic  matrix trace
本文献已被 万方数据 等数据库收录!
点击此处可从《电力自动化设备》浏览原始摘要信息
点击此处可从《电力自动化设备》下载全文