首页 | 本学科首页   官方微博 | 高级检索  
     

Fenton氧化-絮凝组合工艺处理墨盒清洗废水
引用本文:贺凯,袁茂新,陈俊,管运涛,吴光学. Fenton氧化-絮凝组合工艺处理墨盒清洗废水[J]. 水处理技术, 2012, 38(4): 72-76,86
作者姓名:贺凯  袁茂新  陈俊  管运涛  吴光学
作者单位:1. 清华大学环境科学与工程系,北京100084;清华大学深圳研究生院环境工程与管理研究中心,广东深圳518055
2. 常州市城乡建设局,江苏常州,213022
3. 常州市排水管理处,江苏常州,213017
4. 清华大学深圳研究生院环境工程与管理研究中心,广东深圳,518055
摘    要:墨盒清洗废水水质具有色度高、COD高、可生化性差等特点。对墨盒清洗废水采用Fenton氧化-絮凝组合工艺进行处理。Fenton氧化阶段试验研究最佳条件为:H2O2投加量为2 000 mg.L-1,Fe2+/H2O2的质量比为0.05,pH为3,反应时间为120 min。对Fenton氧化后出水进行絮凝试验,絮凝最佳条件为:聚合氯化铝(PAC)投加量为150mg.L-1,pH为8。实际废水经过Fenton-絮凝组合工艺处理后,出水TOC质量浓度为28 mg.L-1,色度为10度,相应的TOC去除率为92%,色度去除率为98.7%,出水符合排放标准。

关 键 词:墨盒清洗废水  Fenton氧化  絮凝  色度

TREATMENT OF INK-CARTRIDGE-WASHING WASTEWATER BY THE COMBINED FENTON-OXIDATION AND FLOCCULATION PROCESS
He Kai , Yuan Maoxin , Chen Jun , Guan Yuntao , Wu Guangxue. TREATMENT OF INK-CARTRIDGE-WASHING WASTEWATER BY THE COMBINED FENTON-OXIDATION AND FLOCCULATION PROCESS[J]. Technology of Water Treatment, 2012, 38(4): 72-76,86
Authors:He Kai    Yuan Maoxin    Chen Jun    Guan Yuntao    Wu Guangxue
Affiliation:1.Department of Environmental Science and Engineering,Tsinghua University,Beijing 10084,China;2.Research Center for Environmental Engineering & Management,Graduate School at Shenzhen,Tsinghua University,Shenzhen 518055,China;3.Urban and Rural Construction Bureau of Changzhou 213022,China;4.Changzhou Drainage Administration,Changzhou 213017,China)
Abstract:Ink-cartridge-washing wastewater had characteristics of high color,high COD concentrations,and low biodegradability.In this study,ink-cartridge-washing wastewater was treated by the combined Fenton-oxidation and flocculation process.The optimal conditions for the Fenton-oxidation treatment were:H2O2 dosage of 2 000 mg.L-1,Fe2+/H2O2 ratio of 0.05,pH of 3,and reaction duration of 120 min.Flocculating the effluent wastewater after the Fenton-oxidation treatment,the optimal conditions were:PAC dosage of 150 mg.L-1 and pH of 8.After treating by the combined Fenton-oxidation and flocculation process,water quality met the national discharging standard;the treated wastewater had TOC concentration of 28 mg.L-1 and color of 10,and the corresponding removal percentages were 92% and 98.7,respectively.
Keywords:ink-cartridge-washing wastewater  fenton-oxidation  flocculation  color