摘    要:通过对采用了地源热泵技术的某办公楼空调系统进行能效测评,对热泵机组的性能和热泵空调系统的性能进行现场检测,依据测试结果评估了项目的节能效益、环境效益和经济效益。通过案例分析,为地源热泵可再生能源利用技术的实际节能效果测评提供了理论依据和借鉴。

关 键 词:地源热泵  能效测评  可再生能源

Energy Efficiency Evaluation and Case Analysis of Ground-Source Heat Pump System
Abstract:The energy efficiency evaluation is conducted for the air conditioning system using ground-source heat pump in an office building. The performances of heat pump unit and air conditioning system are tested in field. The benefits of energy efficiency, environment and economy are assessed accord-ing to the test results. This case analysis provides theory foundation and reference for real energy saving effect evaluation of ground-source heat pump system.