首页 | 本学科首页   官方微博 | 高级检索  
     

配CFB锅炉的300MW机组汽轮机暖机效果探讨
引用本文:丁勇富.配CFB锅炉的300MW机组汽轮机暖机效果探讨[J].热力发电,2010,39(3).
作者姓名:丁勇富
作者单位:大唐红河发电有限责任公司,云南,开远,661600
摘    要:针对300 MW机组的循环流化床(CFB)锅炉冷态起动、汽轮机中速暖机过程中遇到的如主再热汽温无法提升,主汽压力异常升高,过热度下降,汽轮机暖机效果无法保证等问题,分别从锅炉起动初期运行调整和汽轮机运行控制两方面进行分析,并提出了相应的解决方法。实施后,取得了良好的汽轮机暖机效果。

关 键 词:300  MW机组  循环流化床(CFB)锅炉  起动  汽轮机  暖机

AN APPROACH TO WARM-UP EFFETIVENESS OF STEAM TURBINE EQUIPPED FOR 300 MW CFB UNIT
DING Yong-fu.AN APPROACH TO WARM-UP EFFETIVENESS OF STEAM TURBINE EQUIPPED FOR 300 MW CFB UNIT[J].Thermal Power Generation,2010,39(3).
Authors:DING Yong-fu
Affiliation:DING Yong-fuDatang Honghe Power Generation Co Ltd,Kaiyuan 661600,Yunnan Province,PRC
Abstract:Directing against problems encountered in the process of cold-state start-up of boiler and medium speed warm-up of the steam turbine for the first 300 MW CFB unit manufactured in China,such as the temperature of main reheated steam is unable to be risen,the main steam pressure being abnormally enhanced,superheat degree being lowered,and the effectiveness of steam turbine warm-up being unable to be ensured etc.,analysis has been carried out from two aspects,i.e.operation adjustment in initial period of boile...
Keywords:300 MW CFB boiler  start-up  steam turbine  warm-up  operation parameter  