首页 | 本学科首页   官方微博 | 高级检索  
     

国产300MW机组除氧器暂态过程试验研究
引用本文:田丰,徐之昌,刘务波.国产300MW机组除氧器暂态过程试验研究[J].中国电机工程学报,2003,23(2):177-182.
作者姓名:田丰  徐之昌  刘务波
作者单位:1. 广东省电力试验研究所,广东,广州,510600
2. 韶关发电厂,广东,韶关,512132
摘    要:大型机组除氧器暂态过程一直是机组安全运行广为关注的问题,文中通过对某国产300MW机组在功率突变工况下,除氧器有关参数的测量和计算,利用热力学第一定律建立了除氧器热平衡方程,得出机组在该工况下给水泵不会发生汽蚀的结论。原因为供至除氧器的抽汽压力虽然下降,其他汽源的存在阻止除氧器压力(给水焓值)的过快降低,给水泵密封水的回水引入前置泵入口,降低了该处水温,使下降速度较除氧水箱水温延缓的现象水明显,指出该型设计的300MW国产机组除氧器的设计标高可以进一步降低,节省大量的土建投资,而对前置泵入口滤网的堵塞现象应引起充分重视。

关 键 词:国产300MW机组  除氧器  暂态过程  试验  锅炉
文章编号:0258-8013(2003)02-0177-06
修稿时间:2002年4月25日

A TESTING STUDY ON TRANSIENT PROCESS OF DEAERATOR ADAPTED BY NATION-MADE 300MW UNITS
TIAN Feng,XU Zhi-chang,LIU Wu-bo.A TESTING STUDY ON TRANSIENT PROCESS OF DEAERATOR ADAPTED BY NATION-MADE 300MW UNITS[J].Proceedings of the CSEE,2003,23(2):177-182.
Authors:TIAN Feng  XU Zhi-chang  LIU Wu-bo
Abstract:The transient process of the deaerator fitted for a large capacity generating unit is a matter closing related to the power plant safety operation, and therefor, it has been generally concerned by now, this paper presents a method by using some relative values of the deaerator parameters measured to calculated a nation-made 300MW unit during its power output saltation, a heat balance equation for the deaerator has been established according to the First Law of Thermodynamics. The results of calculation show that in such case there is no cavitation on feed water pump. The reason is that when the extraction steam pressure falls down, here some other steam source inlet to the deaerator and increase immediately that prevent the pressure inside the deaerator from falling too fast and the back sealing water of the feed water pump inducts to the booster pump to reduce the feed water temperature, so that the phenomenon of temperature decay is faster then water in the deaerator container. All those processes are not prominent (i.e. smoothly). This leads to a conclusion that the design elevation of deacrator may by lowered more, it can give a great deal of construction investments-saving and the congestion phenomenon in booster pump intake should be greally emphassiged.
Keywords:domestic 300MW units  deaerator  transient procedures  feeding water pump unit  cavitation  testing study
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号