Abstract: | The performances of two systems using hydrocarbon pairs are compared. The first system is an absorption heat pump, comprising a rectification column separator and a mixer comprising a single-stage cell. In this case, five hydrocarbon pairs are used. In the second system, the authors compare the performances of three hydrocarbon pairs in two heat pumps with one or two stages in the mixer. It was shown that the best performances are obtained using pairs with the most similar chemical compositions. |