首页 | 本学科首页   官方微博 | 高级检索  
     

基于PSCAD/EMTDC逆变器自定义定关断角控制的实现
引用本文:董曼玲,谢施君,贺恒鑫,黎小林,黄莹,张丹丹,何俊佳. 基于PSCAD/EMTDC逆变器自定义定关断角控制的实现[J]. 南方电网技术, 2009, 3(1): 36-40
作者姓名:董曼玲  谢施君  贺恒鑫  黎小林  黄莹  张丹丹  何俊佳
作者单位:1. 华中科技大学电气与电子工程学院,武汉,430074
2. 南方电网技术研究中心,广州,510623
基金项目:“十一五“国家科技支撑计划重大项目(2006BAA02A21)
摘    要:在PSCAD中建立了关断角测量模块及定关断角闭环控制框图,从而构建了自定义定关断角闭环控制模块。取代CIGRE原有的标准控制模型,采用所建立的自定义定关断角控制模块对高压直流输电系统的阀控进行了仿真,将结果与标准控制模型下的结果进行了对比,验证了自定义的闭环定关断角控制模块具有良好的动态及静态控制性能,且与标准的CIGRE控制系统具有完全的等价性。同时,针对实际系统的一些故障情况,可以对自定义的定关断角控制模块进行结构优化。使系统具有一定的故障保护功能。总之,自定义的定关断角控制模块为实际的复杂系统实现PSCAD建模和仿真分析提供了更为有效的手段。

关 键 词:HVDC  关断角测量  定关断角控制  闭环控制  自定义控制模块
收稿时间:2008-09-15

Realization of Self-Defined Control Module for Constant Extinction Angle Control in PSCAD/EMTDC
DONG Man-ling,XIE Shi-jun,HE Heng-xing,LI Xiao-lin,HUANG Ying,ZHANG Dan-dan and HE Jun-jia. Realization of Self-Defined Control Module for Constant Extinction Angle Control in PSCAD/EMTDC[J]. Southern Power System Technology, 2009, 3(1): 36-40
Authors:DONG Man-ling  XIE Shi-jun  HE Heng-xing  LI Xiao-lin  HUANG Ying  ZHANG Dan-dan  HE Jun-jia
Affiliation:College of Electrical and Electronic Engineering, Huazhong University of Science and Technology;College of Electrical and Electronic Engineering, Huazhong University of Science and Technology;College of Electrical and Electronic Engineering, Huazhong University of Science and Technology;CSG Technology Research Center;CSG Technology Research Center;College of Electrical and Electronic Engineering, Huazhong University of Science and Technology;College of Electrical and Electronic Engineering, Huazhong University of Science and Technology
Abstract:A new constant-extinction-angle measurement module and a logic chart for close loop control in PSCAD are built up, and thus a self-defined close-loop control module is available for constant extinction angle control. Simulation analysis on the thyristor control of actual HVDC systems is carried out with the new self-defined module, instead of the original CIGRE module in PSCAD. By comparing the simulation results to that from the original module, it is concluded that the new self-defined control module has better characteristics of both dynamic control and static control, and has complete equivalence to the original module. In addition, the new self-defined module can be optimized in configuration against some failures occurred in the actual system so that it is possible to provide protective functions to the system. In a word, the new self-defined module is an effective means for PSCAD/EMTDC simulation analysis to the actual HVDC system.
Keywords:HVDC   constant-extinction-angle measurement   constant-extinction-angle control   close-loop control   self-defined control module
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《南方电网技术》浏览原始摘要信息
点击此处可从《南方电网技术》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号