首页 | 本学科首页   官方微博 | 高级检索  
     


Experimental study on condensation heat transfer enhancement and pressure drop penalty factors in four microfin tubes
Authors:D Han
Affiliation:a Institute of Advanced Machinery Design, Korea University, Seoul 136-713, Korea
b Department of Mechanical Engineering, Korea University, 5ka-1 Anam-dong, Sungbuk-gu, Seoul 136-713, Korea
Abstract:Heat transfer and pressure drop characteristics of four microfin tubes were experimentally investigated for condensation of refrigerants R134a, R22, and R410A in four different test sections. The microfin tubes examined during this study consisted of 8.92, 6.46, 5.1, and 4 mm maximum inside diameter. The effect of mass flux, vapor quality, and refrigerants on condensation was investigated in terms of the heat transfer enhancement factor and the pressure drop penalty factor. The pressure drop penalty factor and the heat transfer enhancement factor showed a similar tendency for each tube at given vapor quality and mass flux. Based on the experimental data and the heat-momentum analogy, correlations for the condensation heat transfer coefficients in an annular flow regime and the frictional pressure drops are proposed.
Keywords:Microfin tube  Condensation  Heat transfer  Pressure drop  Correlations
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号