首页 | 本学科首页   官方微博 | 高级检索  
     


Performance analysis of a room temperature rotary magnetic refrigerator for two different gadolinium compounds
Authors:L.A. Tagliafico   F. Scarpa   F. Canepa  S. Cirafici
Affiliation:

aDipartimento di Ingegneria della Produzione, Termo-Energetica e Modelli Matematici/Sezione di Termo-Energetica e Condizionamento Ambientale, Via all'Opera Pia 15-A, 16145 Genova, Italy

bDipartimento di Chimica e Chimica Industriale, Via Dodecaneso 31, 16145 Genova, Italy

Abstract:A thermodynamic performance analysis is developed for a Steyert-like rotary magnetic refrigeration (RMR) system operating in the near-room temperature range with two possible, alternative, gadolinium compounds. The first magnetocaloric material (MCM) is an alloy (Gd7Pd3) with a well defined Curie temperature (around 318 K), while the second MCM (Gd76Pd24) is an eutectic compound with a smoothed double Curie transition (at 298 and 318 K, respectively).

The main issues linked to the thermodynamic properties of the magnetic material are outlined and the influence of the magnetocaloric properties on the global performance (useful effect, coefficient of performance, and so on) of the refrigeration system is discussed.

Keywords:Magnetic refrigerator   Modelling   Heat transfer   COP   Parameter   Alloy   Gadolinium