防老剂RD脱水塔腐蚀原因分析及防治措施
引用本文:王惠兰.防老剂RD脱水塔腐蚀原因分析及防治措施[J].化工设备与管道,2006,43(1):27-30.
作者姓名:王惠兰
作者单位:南京化工厂,南京,210038
摘    要:介绍了脱水塔的开裂情况,通过采用光学显微镜、扫描电镜、能谱仪等设备对裂纹的形貌、腐蚀产物进行了分析,结果表明该设备产生裂纹的主要原因是应力腐蚀(碱脆),并提出一些有效的防治措施.

关 键 词:脱水塔  应力腐蚀  残余应力  金相组织
文章编号:1009-3281(2006)01-0027-04
收稿时间:2004-08-31
修稿时间:2004年8月31日

Cause Analysis and Protection Methods of Corrosion Occurred in Dehydration Tower with RD
Wang Huilan.Cause Analysis and Protection Methods of Corrosion Occurred in Dehydration Tower with RD[J].Process Equipment & Piping,2006,43(1):27-30.
Authors:Wang Huilan
Affiliation:Nanjing Chemical Plant,Nanjing 210038
Abstract:The cracking occurred in dehydration tower was described in this article. By using optical microscope, scanning electron microscope and energy--depressive spectrum equipment, the shape of the cracks and the products of corrosion were analyzed. It was proved that the main cause of crack was stress corrosion. Then, some useful protecting methods were presented.
Keywords:dehydration tower  stress corrosion  residual stress  metallographic structure
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号