首页 | 本学科首页   官方微博 | 高级检索  
     

扫描镜非接触式检测系统的位置误差分析
引用本文:王洋,颜昌翔,汪逸群,高志良.扫描镜非接触式检测系统的位置误差分析[J].红外与激光工程,2013,42(7):1804-1808.
作者姓名:王洋  颜昌翔  汪逸群  高志良
作者单位:1.中国科学院长春光学精密机械与物理研究所,吉林 长春 130033;
基金项目:国家863计划(2011AA12A103);中国地质调查局工作项目
摘    要:为了满足非接触式扫描镜检测系统的位置检测精度要求,分析系统各误差源对扫描镜位置检测精度的影响,制定详细的系统总体误差分配方案。分析系统的主要误差源,根据系统相关参数,利用齐次坐标转换法,建立系统引入误差量的数学模型,计算各误差源的误差传递系数;参考误差传递系数,根据加工、装调和检测水平相关数据,应用蒙特卡罗法分析计算,进行误差分配。结果表明,目前的加工、装调能力无法达到该系统的精度要求,提出了一种依据目前的检测水平进行误差分配的方法,最终应用误差补偿实现扫描镜位置检测极限误差优于2.5。采用一字线激光器作为光源,通过0.5莱卡经纬仪和千分表进行检测,达到系统要求的检测精度。

关 键 词:扫描镜    误差分析    坐标变换    蒙特卡罗法
收稿时间:2012-11-04

Position error analysis on non-contact testing system of scanning mirror
Wang Yang , Yan Changxiang , Wang Yiqun , Gao Zhiliang.Position error analysis on non-contact testing system of scanning mirror[J].Infrared and Laser Engineering,2013,42(7):1804-1808.
Authors:Wang Yang  Yan Changxiang  Wang Yiqun  Gao Zhiliang
Affiliation:1.Changchun Institute of Optics,Fine Mechanics and Physics,Chinese Academy of Sciences,Changchun 130033,China;2.University of Chinese Academy of Sciences,Beijing 100049,China
Abstract:In order to meet the requirements of the non-contact detection system's position detection accuracy which was applied to detect the movement characteristics of scanning mirror. The analysis on various error sources of the detection system was made and all the errors which affect the position detection accuracy of the scanning mirror were detailed. The mathematical model with errors was set up and the transferring coefficients of the error sources were calculated based on the coordinate transformation method and the relevant parameters of the system. According to the error transferring coefficients and the related data of the current processing and assembly, the calculation of error distribution was given with the Monte Carlo method. The results show that the current processing, assembly capacity can't meet the accuracy requirements of the system, and a new method of the error distribution based on the current detection was put forward. The scanning mirror position detection limits of error was better than 2.5. In order to realize the detection accuracy of the system requirements, the line laser was used as the light source, and the 0.5 Lycra theodolite and micrometer were applied to detect the assembly.
Keywords:scanning mirror  error analysis  coordinate transformation  Monte Carlo method
本文献已被 万方数据 等数据库收录!
点击此处可从《红外与激光工程》浏览原始摘要信息