Young’s modulus and interlaminar fracture toughness of SU-8 film on silicon wafer
Authors:Shun-Fa Hwang  Jia-Hong Yu  Bau-Jang Lai  Hsien-Kuang Liu
Affiliation:

aDepartment of Mechanical Engineering, National Yunlin University of Science and Technology, 123 University Road, Section 3, Douliu 640, Taiwan, ROC

bDepartment of Mechanical and Computer Aided Engineering, Feng Chia University, 100 Wenhwa Road, Taichung 407, Taiwan, ROC

Abstract:SU-8 cantilever beams deposited on the polished sides or unpolished sides of silicon wafers were fabricated by MEMS and bulk micro-machining techniques. Bending tests were conducted to measure the Young’s modulus and interface fracture toughness. The results indicate that the Young’s modulus is increasing as the width of specimens is increasing because the specimen quality becomes better. When the width of SU-8 cantilever beam is 400 μm, the Young’s modulus is about 3.5 GPa. On the other hand, since the interface between SU-8 and silicon wafer does not suffer the attack of etchant, the measured interface fracture toughness has no clear dependence on the specimen width. The averaged interface fracture toughness is about 25–30 J/m2 for the polished interface and 15–20 J/m2 for the unpolished interface.
Keywords:Young’s modulus  Interface fracture toughness  SU-8 photoresist  Micro-cantilever beam