首页 | 本学科首页   官方微博 | 高级检索  
     

1025t/h锅炉冷灰斗处水冷壁管爆漏分析
引用本文:郭臣,张仁奇.1025t/h锅炉冷灰斗处水冷壁管爆漏分析[J].贵州电力技术,2010(6):13-14.
作者姓名:郭臣  张仁奇
作者单位:贵州电力试验研究院,贵州贵阳550002
摘    要:贵州某电厂一台1025t/h锅炉在运行过程中发生前墙冷灰斗处的水冷壁管爆破,采用了金相组织观察,化学成分分析及硬度试验等方法分析了水冷壁爆管的原因。结果表明:水冷壁管的强度偏低、焊接熔合线处过大的附加应力是爆破产生的主要原因。

关 键 词:水冷壁  附加应力  爆管

Analysis on bursting in water cooled wall tubes of ash hopper of a 1025t/h boiler
Guo Chen,Zhang Renqi.Analysis on bursting in water cooled wall tubes of ash hopper of a 1025t/h boiler[J].Guizhou Electric Power Technology,2010(6):13-14.
Authors:Guo Chen  Zhang Renqi
Affiliation:( Guizhou Electric Power Testing&Research Institute, Guiyang 550002 Guizhou, China)
Abstract:The waterwall tubes of ash hopper in front wall of 1025t/h boiler burst during operation in a power plant in Guizhou. In this paper, the reasons of tube - bursting have been analyzed by means of metallographic analysis, chemical elements analysis , hardness testing, etc. The results show that the low cross - intensity of waterwall tubes and excessive additional stress in weld bonds are chief reasons of tube - bursting.
Keywords:waterwall  additional stress  tube - bursting
本文献已被 维普 等数据库收录!