首页 | 本学科首页   官方微博 | 高级检索  
     

广东地区联通标准局房的空调节能措施探索
引用本文:张弢,杨猛.广东地区联通标准局房的空调节能措施探索[J].邮电设计技术,2010(10):23-27.
作者姓名:张弢  杨猛
作者单位:[1]中讯邮电咨询设计院有限公司,河南郑州450007 [2]中国联合网络通信集团有限公司,北京100140
摘    要:以厂东地区联通标准局房为研究对象,提出了通信机房空调精确下送风和空调室外机采用潜热过渡冷却节能装置的节能方式及其实施措施。

关 键 词:通信机房  精确下送风  节能装置  节能措施

Exploration of the Energy Saving Measures of Air conditioning in the Standardized China Unicom's Equipment Building in Guangdong Area
Zhang Tao,Yang Meng.Exploration of the Energy Saving Measures of Air conditioning in the Standardized China Unicom's Equipment Building in Guangdong Area[J].Designing Techniques of Posts and Telecommunications,2010(10):23-27.
Authors:Zhang Tao  Yang Meng
Affiliation:1. China Information Technology Designing & Consulting Institute Co., Ltd.,Zhengzhou 450007,China;2.China United Network Communications Group Co. ,Ltd. ,Beijing 100140,China )
Abstract:Taking the standardized China Unicorn equipment building in Guangdong area as example,it gives 2 energy saving methods,the way of accurate and under airing of air conditioning and the using of energy saving equipment of the latent heat cooling. Finally it gives the energy saving measures.
Keywords:Equipment building  Accurate and under airing  Energy saving equipment  Energy saving measures