摘    要:中性盐腐蚀是一类隐蔽性较大的腐蚀类型。炉水品质可解析为6个基本状态;参数ROHMA可描述各状态的腐蚀特性;参数M描述各状态的腐蚀烈度;参数EC=∫Mdt描述炉管可能遭受腐蚀的程度。在此基础上勾勒出一种“腐蚀诊断系统”的框架。

关 键 词:中性盐腐蚀  炉水品质状态  参数ROHMA  参数M  参数EC=∫Mdt

State Analysis of Neutral Salt Corrosion and Water Quality of Boiler Tubes and Corrosion Diagnosis Framework
Yang Hailang.State Analysis of Neutral Salt Corrosion and Water Quality of Boiler Tubes and Corrosion Diagnosis Framework[J].Electric Power,1997,30(6):28-31.
Authors:Yang Hailang
Affiliation:Yang Hailang
Abstract:This paper describes and anti wearing experiment of the powerline hardwares for protection of ultrahigh voltage (500 kV), large span transimission lines. Two round of the simulation experiments were completed in our laboratary by simulating conductor. The hardwares subjected galloping on transmission line for about 120 000 times. The results identified many relevant parameters which can be used to modify hardware dsign to reduce transmission line wearing due to galloping. The resulet are satisfactory.
Keywords:transimission lines  anti  wearing experiment  hardware for protecting lines  