1025t/h循环流化床锅炉外置式换热器的改造
引用本文:牛树赟.1025t/h循环流化床锅炉外置式换热器的改造[J].发电设备,2012,26(4):303-305.
作者姓名:牛树赟
作者单位:云南大唐国际红河发电有限责任公司,开远,661600
摘    要:针对某厂1 025t/h循环流化床锅炉外置式换热器中温过热器Ⅱ存在的磨损、爆管问题,分析了其结构上存在的不足和由振动碰摩而造成爆管的原因,并从防磨角防振方面提出改造措施。实践证明改造是有效的。

关 键 词:循环流化床锅炉  外置换热器  磨损  改造

Retrofit on the External Heatchanger of a 1 025 t/h CFB Boiler
NIU Shu-yun.Retrofit on the External Heatchanger of a 1 025 t/h CFB Boiler[J].Power Equipment,2012,26(4):303-305.
Authors:NIU Shu-yun
Affiliation:NIU Shu-yun (Yunnan Datang International Honghe Power Generation Co., Ltd., Kaiyuan 661600, China)
Abstract:Regarding wearing and tube rupture issues of the external medium-temperature superheater II for the 1 025 t/h CFB boiler of a power plant, causes leading to above problems are analyzed, such as the deficiency in structure and the rub-impact faults due to vibration. For anti-wear and anti-vibration purposes, corresponding countermeasures are put forward, which are proved to be effective in solving above problems.
Keywords:CFB boiler  external heatchanger  wear  retrofit