Abstract:The transient and setpoint simulation small and medium reactor (TASS/SMR) code has been applied to perform the safety analysis and performance evaluation of an integral type pressurized water reactor. Till now, the code has only been verified by using simplified and analytical problems as well as a reliable system code due to the lack of available experimental data. Recently, several kinds of experiments have been performed by focusing on an identification of the heat transfer characteristics at a heat sink and source, and the thermal hydraulic characteristics and the natural circulation performance in an integral effect test facility. In this paper, the TASS/SMR code has been validated by using the experimental data obtained from a separate effect test facility by focusing on the heat transfer characteristics and an integral effect test facility by focusing on the thermal hydraulic characteristics and the natural circulation performance. According to the validation results of the TASS/SMR code against the separate effect test and the integral effect test, the code predicts the overall variation of the thermal hydraulic parameters well, including the system pressure, fluid temperature, mass flow rate, etc., and it is applicable for the safety analysis and performance evaluation of an integral type pressurized water reactor.