摘    要:介绍了广东医学院附属医院排污和排水管道施工的具体情况,分析了该医院明挖排污和排水管道接口抹带施工的质量通病,并针对性地提出了具体的防治措施,从而解决明挖施工排污和排水管道中遇到的问题。

关 键 词:排污和排水管道  接口  质量  防治措施

Quality control of junction plaster band between successive drain pipes in hospital open-cut trench
HAN Ji-guang. Quality control of junction plaster band between successive drain pipes in hospital open-cut trench[J]. Shanxi Architecture, 2008, 34(18): 179-180
Authors:HAN Ji-guang
Affiliation:HAN Ji-guang
Abstract:It introduces the details of the drain pipes construction of the hospital attached to Guangdong Medical College,analyses the common quality problems in the junction plaster band between successive drain pipes,and puts forward detailed preventive measures on them,which solves the problems in the open-cut trench construction of junction plaster band between successive drain pipes.