首页 | 本学科首页   官方微博 | 高级检索  
     


Evaluation of two cooling systems under a firefighter coverall
Authors:Lennart PJ Teunissen  Li-Chu Wang  Shih-Nung Chou  Chin-hsien Huang  Gwo-Tsuen Jou  Hein AM Daanen
Affiliation:1. TNO, PO Box 23, 3769 ZG Soesterberg, The Netherlands;2. Taiwan Textile Research Institute, No. 6, Chengtian Rd., Tucheng Dist., New Taipei City 23674, Taiwan, ROC;3. MOVE Research Institute, Faculty of Human Movement Sciences, VU University Amsterdam, Van der Boechorststraat 9, 1081 BT Amsterdam, The Netherlands
Abstract:Firemen often suffer from heat strain. This study investigated two chest cooling systems for use under a firefighting suit. In nine male subjects, a vest with water soaked cooling pads and a vest with water perfused tubes were compared to a control condition. Subjects performed 30 min walking and 10 min recovery in hot conditions, while physiological and perceptual parameters were measured. No differences were observed in heart rate and rectal temperature, but scapular skin temperature and fluid loss were lower using the perfused vest. Thermal sensation was cooler for the perfused vest than for the other conditions, while the cool pad vest felt initially cooler than control. However, comfort and RPE scores were similar. We conclude that the cooling effect of both tested systems, mainly providing a (temporally) cooler thermal sensation, was limited and did not meet the expectations.
Keywords:Cooling  Fire fighting garments  Heat stress
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号