DISINTEGRATING EFFECT OF REPEATED FREEZING AND THAWING ON BUILDING BRICK*
Authors:J. F. McMohan  C. R. Amberg
Affiliation:Research Department New York State College of Ceramics Alfred, New York
Abstract:Laboratory freezing and thawing tests (A.S.T.M. test No. C47–44 and modifications thereof) were correlated with results of outdoor-exposure tests. This correlation was based on saturation coefficient, absorption, rate of absorption, strength, and method of manufacture. New York building brick of the soft-mud and stiff-mud types were investigated. The results show that those brick within a specific absorption range and with the greatest strength and the smallest saturation coefficient will have lower loss in the freezing-thawing tests.