首页 | 本学科首页   官方微博 | 高级检索  
     

铝制板翅式换热器事故的分析与防范
引用本文:张和森.铝制板翅式换热器事故的分析与防范[J].深冷技术,2005(4):57-58.
作者姓名:张和森
作者单位:开封市三利制氧设备有限公司,河南开封市新宋路贵都花园5号楼 475002
摘    要:主要分析铝制板翅式换热器在空分设备中应用时被损坏的原因,介绍换热器在制造、维修和使用过程中应采取的必要技术措施。

关 键 词:空分设备  换热器  通道串漏  工艺孔
文章编号:1009-9425(2005)04-0057-02
收稿时间:2005-03-23
修稿时间:2005年3月23日

Analysis of the failure in connection with aluminum brazed plate-fin heat exchangers and preventive measures
Zhang He-sen.Analysis of the failure in connection with aluminum brazed plate-fin heat exchangers and preventive measures[J].Cryogenic Technology,2005(4):57-58.
Authors:Zhang He-sen
Abstract:The causes resulting in the damage of aluminum brazed plate-fin heat exchangers when they are used in an air separation plant are analyzed . In maintenance the necessary technical measures which should be taken in the manufacture ,maintenance and opnation of heat exchangers are mentioned.
Keywords:Air separation plant  Heat exchanger  Inter-leakage in adjacent passages  Fabrication hole
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号