摘    要:叙述了兰溪发电有限公司600MW超临界机组凝结水泵变频器改造的方案及除氧器水位控制逻辑以及改造后的节能情况,指出,通过近半年的运行,再与未改造机组比较,具有明显的经济性。

关 键 词:凝结水泵  变频器改造  控制逻辑  节能分析

Analysis on the Energy Saving Modification of Coagulate Pump Frequency Converter in Lanxi Power Company
LI Yan-meng. Analysis on the Energy Saving Modification of Coagulate Pump Frequency Converter in Lanxi Power Company[J]. Shanxi Energy and Conservation, 2010, 0(4): 43-47
Authors:LI Yan-meng
Affiliation:LI Yan-meng(Zhejiang Zheneng Lanxi power generation Co.Ltd.,Lanxi 321100, Zhejiang, China)
Abstract:This paper introduces the program to modify 600 MW supercritical units coagulate pump frequency converter, de-aerator water level control logic and energy conservation state after transforming. Compared with unites unmodified, unites having been modified are obviously economy after operating 6 months.
Keywords:condensation pump  inverter transformation  control logic  energy analysis