首页 | 本学科首页   官方微博 | 高级检索  
     


Volume ratios for n-pentane in the temperature range 278–338 K and at pressures up to 280 MPa
Authors:A. J. Easteal  L. A. Woolf
Affiliation:(1) Atomic and Molecular Physics Laboratories, Research School of Physical Sciences, The Australian National University, 2601 Canberra, A.C.T., Australia;(2) Present address: Department of Chemistry, University of Auckland, Auckland, New Zealand
Abstract:Volume ratios (VP/V0.1), and isothermal compressibilities calculated from them, are reported for n-pentane for seven temperatures in the range 278 to 338 K for pressures up to 280 MPa. The isobaric measurements were made with a bellows volumometer for which a novel technique had to be devised to enable measurements to be made above the normal boiling point (309.3 K). The accuracy of the volume ratios is estimated to be ±0.05 to 0.1% up to 303.15 K and ±0.1 to 0.2% from 313.15 to 338.15 K. The volume ratios are in good agreement with those calculated from recent literature data up to the maximum pressure of the latter, viz., 60 MPa.
Keywords:high pressure  isothermal compressibility  n-pentane  volume ratio
本文献已被 SpringerLink 等数据库收录!