首页 | 本学科首页   官方微博 | 高级检索  
     

MICROBRIDGE TESTING OF YOUNG'S MODULUS AND RESIDUAL STRESS OF NICKEL FILM ELECTROPLATED ON SILICON WAFER
作者姓名:Y.Zhou  C.S.Yang  J.A. Chen  G.F. Ding  L. Wang  M.J Wang  Y.M Zhang  T.H Zhang
作者单位:Key Laboratory for Thin Film and Microfabrication of Ministry of Education,Research Institute of Micro/Nanometer Science and Technology,Shanghai Jiaotong University,Shanghai 200030,China,Key Laboratory for Thin Film and Microfabrication of Ministry of Education,Research Institute of Micro/Nanometer Science and Technology,Shanghai Jiaotong University,Shanghai 200030,China,Key Laboratory for Thin Film and Microfabrication of Ministry of Education,Research Institute of Micro/Nanometer Science and Technology,Shanghai Jiaotong University,Shanghai 200030,China,Key Laboratory for Thin Film and Microfabrication of Ministry of Education,Research Institute of Micro/Nanometer Science and Technology,Shanghai Jiaotong University,Shanghai 200030,China,Key Laboratory for Thin Film and Microfabrication of Ministry of Education,Research Institute of Micro/Nanometer Science and Technology,Shanghai Jiaotong University,Shanghai 200030,China,Key Laboratory for Thin Film and Microfabrication of Ministry of Education,Research Institute of Micro/Nanometer Science and Technology,Shanghai Jiaotong University,Shanghai 200030,China,Key Laboratory for Thin Film and Microfabrication of Ministry of Education,Research Institute of Micro/Nanometer Science and Technology,Shanghai Jiaotong University,Shanghai 200030,China,State Key Laboratory of Nonlinear Mechanics (LNM),Institute of Mechanics,The Chinese Academy of Sciences,Beijing 100080,China.
摘    要:Microbridge testing is used to measure the Young's modulus and residual stresses ofmetallic films. Nickel film microbridges with widths of several hundred microns arefabricated by Microelectromechanical Systems. In order to measure the mechanicalproperties of nickel film microbridges, special shaft structure is designed to solve theproblem of getting the load--deflection curves of metal film microbridge by Nanoin--denter XP system with normal Berkovich probe. Theoretical analysis of the micro--bridge load--deflection curve is proposed to evaluate the Young's modulus and residualstress of the films simultaneously. The calculated results based on the experimentalmeasurements show that the average Young's modulus and residual stress are around190GPa and 175MPa respectively, while the Young's modulus measured by Nano-hardness method on nickel film with silicon substrate is 186.8±7.34GPa.


MICROBRIDGE TESTING OF YOUNG'S MODULUS AND RESIDUAL STRESS OF NICKEL FILM ELECTROPLATED ON SILICON WAFER
Y.Zhou,C.S.Yang,J.A. Chen,G.F. Ding,L. Wang,M.J Wang,Y.M Zhang,T.H Zhang.MICROBRIDGE TESTING OF YOUNG''''S MODULUS AND RESIDUAL STRESS OF NICKEL FILM ELECTROPLATED ON SILICON WAFER[J].Acta Metallurgica Sinica(English Letters),2004,17(3).
Authors:YZhou  CSYang  JA Chen  GF Ding  L Wang  MJ Wang  YM Zhang  TH Zhang Key Laboratory for Thin Film and Microfabrication of Ministry of Education  Research Institute of Micro/Nanometer Science and Technology  Shanghai Jiaotong University  Shanghai  China State Key Laboratory of Nonlinear Mechanics
Abstract:
Keywords:nickel film microbridge  MEMS  mechanical property  loadeflection measurement
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号