摘    要:大多数火电厂汽包水位的测量都是采用差压水位计作为主要监测手段,为此介绍了引起差压水位计测量误差的几种常见因素,及针对这些常见因素所采取的方法。

关 键 词:汽包差压水位计 误差 因素 反措
收稿时间:2006-06-07

Common Factors Influencing Drum Differential-pressure Water Level Indicators Measuring and Countermeasures
Yan Jian-jun,Lv Fu-zhi. Common Factors Influencing Drum Differential-pressure Water Level Indicators Measuring and Countermeasures[J]. North China Electric Power, 2006, 0(A02): 72-74
Authors:Yan Jian-jun  Lv Fu-zhi
Affiliation:Shanxi Datang International Yungang Thermal Power Co. Ltd. ,Datong 037039,China
Abstract:Differential-pressure water level indicators are now in common use in fossil-fuel power plant. Therefore the common origins of the measuring errors of differential-pressure water level indicators are introduced,and the common countermeasures are discussed.
Keywords:drum differential-pressure water level indicators    errors    factors    countermeasures