A 300 Hz two-stage pulse tube cryocooler that attains 58 K
Authors:Huikun Cai  Luwei Yang  Yuan Zhou
Affiliation:a Key Laboratory of Cryogenics, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, China
b Graduate University of Chinese Academy of Sciences, Beijing 100190, China
Abstract:We present a two-stage pulse tube cryocooler working at 300 Hz driven by a thermoacoustic engine. Compared to the previous experimental results, the combined inertance tube with different diameters that is used in the second stage is found to play the key role in phase shifting and to lead to superior cooling. Two different wall thickness tubes are tested in the experiments. After the optimization, the second-stage cold end achieves a no-load temperature of 57.9 K with an average pressure of 3.8 MPa, and a cooling capacity of 0.5 W at 81.88 K.
Keywords:D. Ultra-high frequency   E. Pulse tube cooler   C. Thermoacoustics