首页 | 本学科首页   官方微博 | 高级检索  
     


Transient thermodynamic behavior of cryogenic mixed fluid thermosiphon and its cool-down time estimation
Authors:Jisung Lee
Affiliation:Cryogenic Engineering Laboratory, Division of Mechanical Engineering, School of Mechanical, Aerospace and Systems Engineering, Korea Advanced Institute of Science and Technology, 335 Gwahangno, Yuseong-gu, Daejeon, 305-701, Republic of Korea
Abstract:Thermosiphon is an efficient heat transfer device by utilizing latent heat of fluid at liquid-vapor phase change. One of the disadvantages of thermosiphon, however, is that the operational temperature range is fundamentally limited from the critical point to the triple point of the working fluid to maintain two phase state. Nitrogen (N2) and tetrafluoromethane (CF4) were selected as the mixed working fluid to widen their original operational temperature range. Thermodynamic behavior of mixture and its effect on the cool-down time were investigated. A simple calculation model was proposed to estimate the cool-down time of the thermosiphon evaporator prior to experiments. The calculated results agreed well with the experimental results within 5% error. The cool-down time reduction was not achieved by mixing two components at once due to the separation of mixture. One idea to avoid this problem was suggested in this paper where the estimated cool-down time was reduced 17.8% compared to pure N2.
Keywords:Gas mixture (B)   Nitrogen (B)   Heat transfer (C)   Phase transitions (C)   Thermodynamics (C)
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏