摘    要:循环流化床锅炉(CFB)在运行中也反映出高温烧蚀、低温腐蚀、冲刷磨损、超温爆管、耐火耐磨材料脱落等问题,针对存在的问题,分析循环流化床锅炉炉膛内水冷壁的磨损情况,提出相应的防磨措施。

关 键 词:循环流化床锅炉  水冷壁  磨损  措施

BRIEF ANALYSIS ON CAUSES FOR WATER-COOLED MEMBRANE WEAR OF CFB BOILER AND COUNTER-MEASURES
Tian Qunwei,Zhou Jinying. BRIEF ANALYSIS ON CAUSES FOR WATER-COOLED MEMBRANE WEAR OF CFB BOILER AND COUNTER-MEASURES[J]. Large Scale Nitrogenous Fertilizer Industry, 2012, 35(2): 121-124
Authors:Tian Qunwei  Zhou Jinying
Affiliation:(Shaanxi Weihe Coal-Chemical Group Co.,Ltd.,Weinan 714000)
Abstract:In the course of running of CFB boiler such probelms as high-temperature erosion,low temperature corrosion,erosion wear,over-temperature tube burst,fall-off of fire-and wear-resistant materials are also reflected and aiming at these problems the wear of water-cooled membrane inside the chamber of CFB boiler is analyzed and corresponding anti-wear measures proposed.
Keywords:CFB boiler  water-cooled membrane  wear  measures