首页 | 本学科首页   官方微博 | 高级检索  
     

二滩水电站泄洪雾化及防护
引用本文:王锋辉.二滩水电站泄洪雾化及防护[J].大坝与安全,2011(5):42-46.
作者姓名:王锋辉
作者单位:二滩水力发电厂,四川攀枝花,610017
摘    要:泄洪雾化是一种具有严重危害性的雾化水流,影响建筑物的正常运行.二滩水电站泄洪强度大,泄洪雾化范围和强度超过了设计预想,对下游护岸的安全防护范围提出了更高的要求.泄洪雾化试验结果及防护效果分析得出,二滩水电站泄洪雾化区的防护范围是适当的,防护方法是可靠的,这是我国首座超过200m高拱坝泄洪雾化防护成功的例证,对其他高坝泄...

关 键 词:二滩水电站  泄洪雾化  防护  改进

Influence of discharging foggy and its protection at Ertan hydropower station
WANG Feng-hui.Influence of discharging foggy and its protection at Ertan hydropower station[J].Large Dam & Safety,2011(5):42-46.
Authors:WANG Feng-hui
Affiliation:WANG Feng-hui Ertan Hydro Power Plant
Abstract:The flood discharging rain and fog at Ertan hydropower station exerted harmful influence on operation of hydraulic structures which required better protection of downstream bank revetment. Test on flood discharging rain and fog was carried out and the protection analysis showed that the protection scope and method were sound and good effect was achieved, worthy reference.
Keywords:Ertan hydropower station  flood discharging rain and fog  protection  improvement
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号