首页 | 本学科首页   官方微博 | 高级检索  
     


Pullout tests of epoxy-coated reinforcement in concrete
Authors:A.R. Cusens  Z. Yu
Affiliation:

Department of Civil Engineering, University of Leeds, Leeds, UK, LS2 9JT

British Rail Research, PO Box 2, Derby, UK, DE24 8YB

Abstract:The bond strength and slip of epoxy-coated reinforcing bars in concrete have been evaluated by carrying out single pullout and double pullout tests. In extended single pullout tests, slip measurements were made while tensile force was applied to reinforcing bars embedded in concrete. In double pullout tests, 20 cycles of load were applied at levels of steel stress between zero and 0·5 times characteristic steel strength. Strains were measured by electrical resistance strain gauges glued inside the bars. Both epoxy-coated and uncoated bars were used in the investigation, to obtain comparative results. The strain gradient along the bar was found to be less for the coated reinforcement. In general, the epoxy coating was found to increase slip in bond and thereby reduce the bond performance of coated bars.
Keywords:Pullout tests   epoxy-coated bars   bond strength   slip   steel strain   steel stress   bond performance
本文献已被 ScienceDirect 等数据库收录!