首页 | 本学科首页   官方微博 | 高级检索  
     

1 000 MW超超临界机组高压旁路异动分析
引用本文:刘磊,张秋生,吴志刚,王富强,张金营. 1 000 MW超超临界机组高压旁路异动分析[J]. 中国电力, 2016, 49(9): 87-92. DOI: 10.11930/j.issn.1004-9649.2016.09.087.06
作者姓名:刘磊  张秋生  吴志刚  王富强  张金营
作者单位:神华国华(北京)电力研究院有限公司,北京 100025
摘    要:为提高上汽-西门子1 000 MW超超临界机组100%高压旁路系统的可靠性,分析和总结了某电厂高压旁路控制阀压力开关误动后的机组重要参数的变化趋势和特点,在不改变原有设计思想和保护原理的基础上,提出了有针对性的热工控制优化策略,提高了机组的整体安全性。上述优化策略已在其他1 000 MW机组中进行了推广应用,验证了优化策略对同类型机组的整体有效性。

关 键 词:超超临界燃煤发电机组  西门子  高压旁路  安全阀  高压排汽温度  低压旁路控制  
收稿时间:2016-03-16

Analysis on the Abnormal Operation of High-Pressure Bypass System of 1 000-MW Ultra-Supercritical Units
LIU Lei,ZHANG Qiusheng,WU Zhigang,WANG Fuqiang,ZHANG Jinying. Analysis on the Abnormal Operation of High-Pressure Bypass System of 1 000-MW Ultra-Supercritical Units[J]. Electric Power, 2016, 49(9): 87-92. DOI: 10.11930/j.issn.1004-9649.2016.09.087.06
Authors:LIU Lei  ZHANG Qiusheng  WU Zhigang  WANG Fuqiang  ZHANG Jinying
Affiliation:Shenhua Guohua (Beijing) Electric Power Research Institute Co., Ltd., Beijing 100025, China
Abstract:In order to improve the reliability of the 100% high-pressure bypass system of 1 000-MW ultra-supercritical units, the variation trends and characteristics of major parameters are analyzed and summarized after the misoperation of a pressure switch in the high-pressure bypass system of a power plant. On the premise of no changes to the original design and protection principles, the optimized thermal control strategies are proposed. By adopting the proposed strategies, the overall security of the unit is improved. These optimized control strategies have been popularized and applied to the 1 000-MW units of the same type, and the effectiveness has been proved.
Keywords:ultra-supercritical coal-fired power generation unit  Siemens  high-pressure bypass  safety valve  high-pressure cylinder exhaust temperature  low-pressure bypass control  