首页 | 本学科首页   官方微博 | 高级检索  
     

某600 MW超临界机组1号瓦振动异常分析与处理
引用本文:黎瑜春,陈涛,杨为民,齐敏芳. 某600 MW超临界机组1号瓦振动异常分析与处理[J]. 中国电力, 2016, 49(11): 135-139. DOI: 10.11930/j.issn.1004-9649.2016.11.135.05
作者姓名:黎瑜春  陈涛  杨为民  齐敏芳
作者单位:1. 国网福建省电力有限公司电力科学研究院,福建 福州 350007;2. 华北电力大学 能源动力与机械工程学院,北京 102206
摘    要:某600 MW超临界机组在460 MW负荷左右进行单阀运行模式切顺序阀运行模式时,1号瓦轴振偏大,顺序阀运行模式无法正常投入,影响机组的经济性。通过采集现场数据,从引起振动异常的机理出发,准确分析了故障原因;通过采取调整轴系标高等手段,消除了该机组1号瓦振动异常的故障,对大型机组类似振动故障分析及处理具有借鉴价值。

关 键 词:火电机组  汽轮发电机组  超临界参数  单阀运行模式  顺序阀运行模式  振动处理  旋转部件  
收稿时间:2016-08-22

Analysis and Treatment of Bearing 1 Vibration Fault in a 600-MW Steam Turbine
LI Yuchun,CHEN Tao,YANG Weimin,QI Minfang. Analysis and Treatment of Bearing 1 Vibration Fault in a 600-MW Steam Turbine[J]. Electric Power, 2016, 49(11): 135-139. DOI: 10.11930/j.issn.1004-9649.2016.11.135.05
Authors:LI Yuchun  CHEN Tao  YANG Weimin  QI Minfang
Affiliation:1. State Grid Fujian Electric Power Research Institute, Fuzhou 350007, China;2. School of Energy Power and Mechanical Engineering, North China Electric Power University, Beijing 102206, China
Abstract:Due to the excessive shaft vibration on Bearing 1 of a 600-MW supercritical unit when it is switched from single valve to sequential valve operation mode at around 460 MW load level, the sequential valve mode cannot be normally committed, which has great impact on the economic performance of the unit. By virtue of field data collection and analysis, the cause of the abnormal vibration is analyzed precisely in the aspect of vibration mechanism. Through shafting level adjustment, the abnormal vibration of Bearing 1 is successfully eliminated. This case is useful for analyzing similar vibration fault in supercritical power plants.
Keywords:thermal power generation unit  steam turbine generator  supercritical parameter  single valve operation  sequence valve operation  vibration treatment  rotary part  
本文献已被 CNKI 等数据库收录!
点击此处可从《中国电力》浏览原始摘要信息
点击此处可从《中国电力》下载全文