首页 | 本学科首页   官方微博 | 高级检索  
     

35 MW循环流化床锅炉二次风机节能改造
引用本文:郭新海,李建锋,王贵良,冷杰,吕磊,祁月琴,吕宏奇,吕俊复.35 MW循环流化床锅炉二次风机节能改造[J].中国电力,2016,49(8):162-166.
作者姓名:郭新海  李建锋  王贵良  冷杰  吕磊  祁月琴  吕宏奇  吕俊复
作者单位:1. 安徽华电六安发电有限公司,安徽 六安 237126; 2. 中国电力企业联合会,北京 100761;3. 北京育林佳业科技有限公司,北京 100080; 4. 国网辽宁省电力有限公司电力科学研究院,辽宁 沈阳 110006;5. 清华大学 热科学与动力工程教育部重点实验室,北京 100084
摘    要:循环流化床锅炉机组因其具有的优良特点适应中国国情而得到了迅速发展,但与煤粉锅炉相比,其特殊的燃烧方式使其必须采用高压头的一次风机与二次风机,造成流化床锅炉电站厂用电率较高。为了提高某135 MW循环流化床锅炉二次风机的效率,对该风机进行了技术改造,即通过在该风机原有叶片中间增加小叶片的方式来提升其效率。改造前后风机性能测试数据表明,改造后风机的流量与效率提升明显,其转速越低,风机性能提高幅度越大。

关 键 词:循环流化床锅炉(CFB)  风机  叶片  节能改造  
收稿时间:2016-03-16

Retrofit of Energy Saving on Secondary Air Fan of a 135-MW CFB boiler
GUO Xinhai,LI Jianfeng,WANG Guiliang,LENG Jie,LV Lei,QI Yueqin,LV Hongqi,LV Junfu.Retrofit of Energy Saving on Secondary Air Fan of a 135-MW CFB boiler[J].Electric Power,2016,49(8):162-166.
Authors:GUO Xinhai  LI Jianfeng  WANG Guiliang  LENG Jie  LV Lei  QI Yueqin  LV Hongqi  LV Junfu
Affiliation:1. Anhui Huadian Lu’an Power Generation Co. Ltd., Lu’an 237126, China; 2. China Electricity Council, Beijing 100761, China;3. Beijing Yulin Jiaye Technology Co., Ltd., Beijing 100080, China; 4. Electric Power Research Institute of State Grid Liaoning Electric Power Supply Co. Ltd., Shenyang 110006, China; 5. Key Laboratory for Thermal Science and Power Engineering of Ministry of Education, Tsinghua University, Beijing 100084, China
Abstract:The CFB boiler is developed rapidly due to its outstanding characteristics suitable to the circumstances in China. However, compared to the pulverized coal boiler, its special combustion style makes it necessary to adopt the high-pressure primary and secondary air fans, which leads to high auxiliary power consumption rate. In order to improve the efficiency of the secondary air fan of a 135-MW circulating fluidized bed (CFB) boiler, the technical retrofit is conducted on the fan by installing small blades between the original blades to enhance its efficiency. The comparison between the fan performance test data before and after the retrofit shows that the flow and the efficiency are improved significantly after the retrofit; the lower the speed is, the larger margin of the fan performance is achieved.
Keywords:CFB  fan  blade  energy saving retrofit  
点击此处可从《中国电力》浏览原始摘要信息
点击此处可从《中国电力》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号