首页 | 本学科首页   官方微博 | 高级检索  
     

锅炉尾部烟道振动原因分析及处理
引用本文:楼杰,蒋建伟. 锅炉尾部烟道振动原因分析及处理[J]. 四川电力技术, 2012, 35(4): 91-94
作者姓名:楼杰  蒋建伟
作者单位:广东粤电靖海发电有限公司,广东揭阳,515223
摘    要:广东惠来电厂2号DG1900/25.4-П2型超临界锅炉出现了尾部烟道振动问题。经试验、分析、计算,认为主要原因是由卡门涡流脱落频率接近设备的声学驻波频率而使设备产生高频共振所致。通过采取加装防振隔板的措施,振动问题得以解决,取得了满意的效果。

关 键 词:600MW超临界锅炉  尾部烟道振动  卡门涡流(涡街)  防振隔板

Cause Analysis on Vibration of Convection Flue Gas Pass in Boiler and Its Treatment
Lou Jie Jiang Jianwei. Cause Analysis on Vibration of Convection Flue Gas Pass in Boiler and Its Treatment[J]. Sichuan Electric Power Technology, 2012, 35(4): 91-94
Authors:Lou Jie Jiang Jianwei
Affiliation:Lou Jie Jiang Jianwei
Abstract:The phenomenon about the vibration of convection flue gas pass in No. 2 DG1900/25.4 -172 supercritical boiler of Guangdon Huilai Power Plant are introduced. After the tests, analyses and calculations, the main causes of the vibration are obtained that is caused by high - frequency resonance due to Karman vortex shedding frequency being close to the acoustic standing - wave frequency of the equipment. Some measures such as installing the antivibration baffle are proposed to solve the vibration problem, which meets with satisfactory results.
Keywords:600 MW supercritical boiler  vibration of convection flue gas pass  Karman vortex (Karman vortex street)  antivibration baffle
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《四川电力技术》浏览原始摘要信息
点击此处可从《四川电力技术》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号